About Home
Inspection Company
Residential * Commercial * Environmental
Common Defects
Electrical InspectionElectrical Inspection
Electrical service wire contacting flue at roof Electrical service wire contacting flue at roof
Electrical InspectionElectrical Inspection
Incoming electrical service entry wire below 9' above gradeIncoming electrical service entry wire below 9' above grade
Electrical InspectionElectrical Inspection
Double tapping of two electrical circuit wires into a single breakerDouble tapping of two electrical circuit wires into a single breaker
Electrical InspectionElectrical Inspection
Wire splices not in a junction box with a coverWire splices not in a junction box with a cover
Electrical InspectionElectrical Inspection
Damaged/bent electrical service mastDamaged/bent electrical service mast
Electrical InspectionElectrical Inspection
Unsafe or non-professional electrical wiringUnsafe or non-professional electrical wiring
Electrical InspectionElectrical Inspection
Missing stress relief bushings at electrical wire penetrationsMissing stress relief bushings at electrical wire penetrations
Electrical InspectionElectrical Inspection
Pest entry to electrical panel enclosuresPest entry to electrical panel enclosures
Electrical InspectionElectrical Inspection
Separation of the incoming electrical service lateral conduitSeparation of the incoming electrical service lateral conduit
Electrical InspectionElectrical Inspection
Overhead electrical service wiring contacting roof.Overhead electrical service wiring contacting roof.
Electrical InspectionElectrical Inspection
Electrical circuit wiring not concealed in conduitElectrical circuit wiring not concealed in conduit
HVAC InspectionHVAC Inspection
Rusted out HVAC sub slab ductingRusted out HVAC sub slab ducting
HVAC InspectionHVAC Inspection
Non professional HVAC ducting installationNon professional HVAC ducting installation
HVAC InspectionHVAC Inspection
Backdrafting and overheating of the furnaceBackdrafting and overheating of the furnace
HVAC InspectionHVAC Inspection
Flexible gas lines penetrating the VHAC furnace cabinetFlexible gas lines penetrating the VHAC furnace cabinet
HVAC InspectionHVAC Inspection
Homeowner improper HVAC ducting additionsHomeowner improper HVAC ducting additions
HVAC InspectionHVAC Inspection
Clogged condensate drain lines resulting in moisture/corrosion at the base of the HVAC furnaceClogged condensate drain lines resulting in moisture/corrosion at the base of the HVAC furnace
HVAC InspectionHVAC Inspection
Detached HVAC flue connections from gas fired appliancesDetached HVAC flue connections from gas fired appliances
HVAC InspectionHVAC Inspection
Missing HVAC flue cap at roofMissing HVAC flue cap at roof
Fireplace InspectionFireplace Inspection
Blocked Fireplace Flue at chimney at roofBlocked Fireplace Flue at chimney at roof
Fireplace InspectionFireplace Inspection
Freeze damage to fireplace brick at roofFreeze damage to fireplace brick at roof
Fireplace InspectionFireplace Inspection
Cracked crown & missing cap at chimney at roofCracked crown & missing cap at chimney at roof
Fireplace InspectionFireplace Inspection
Metal flue contacting attic framingMetal flue contacting attic framing
Fireplace InspectionFireplace Inspection
Cracked flue tile visible at roofCracked flue tile visible at roof
Plumbing InspectionPlumbing Inspection
Rust/scale on hot water tank burnerRust/scale on hot water tank burner
Attic InspectionAttic Inspection
Missing insulation above an additionMissing insulation above an addition
Mold InspectionMold Inspection
Mold growing on cabinet surfaces at vacant houseMold growing on cabinet surfaces at vacant house
Mold InspectionMold Inspection
Mold on drywall adjacent to a leaking shower enclosureMold on drywall adjacent to a leaking shower enclosure
Pest InspectionPest Inspection
Wood Bee pest damageWood Bee pest damage
Pest InspectionPest Inspection
Termite pest damage to floor joistTermite pest damage to floor joist
Wood Rot InspectionWood Rot Inspection
Moisture damaged sub floor from plumbing leak under a ceramic shower enclosureMoisture damaged sub floor from plumbing leak under a ceramic shower enclosure
Pest InspectionPest Inspection
"Bats" in an attic gable vent"Bats" in an attic gable vent
Pest InspectionPest Inspection
Termite pest shelter tube on a foundation wallTermite pest shelter tube on a foundation wall
Plumbing InspectionPlumbing Inspection
Leaking shower pan under a tile shower enclosure from plumbing leakLeaking shower pan under a tile shower enclosure from plumbing leak
Plumbing InspectionPlumbing Inspection
Leaking/damaged hot water tank plumbing connectionsLeaking/damaged hot water tank plumbing connections
Plumbing InspectionPlumbing Inspection
Non Professional plumbing repairNon Professional plumbing repair
Roof InspectionRoof Inspection
Under ventilated attic roof covering damageUnder ventilated attic roof covering damage
Roof InspectionRoof Inspection
No rain diverter on the back side of the chimney at the roofNo rain diverter on the back side of the chimney at the roof
Roof InspectionRoof Inspection
Tree contact damage? to roofTree contact damage? to roof
Roof InspectionRoof Inspection
Hail impact to metal roofingHail impact to metal roofing
Roof InspectionRoof Inspection
Improper flashing at the roof/wall contactImproper flashing at the roof/wall contact
Roof InspectionRoof Inspection
Roof Leak?Roof Leak?
Roof InspectionRoof Inspection
Non professional roof repairsNon professional roof repairs
Roof InspectionRoof Inspection
Roof Support????Roof Support????
Fireplace InspectionFireplace Inspection
Missing chimney flue tile in-filled with non fire rated veneer brick visible at the roofMissing chimney flue tile in-filled with non fire rated veneer brick visible at the roof
Fireplace InspectionFireplace Inspection
Unlined brick chimney visible at the roofUnlined brick chimney visible at the roof
Structure InspectionStructure Inspection
Settlement of the foundation wall and shimming with wood shimsSettlement of the foundation wall and shimming with wood shims
Structure InspectionStructure Inspection
Outward foundation wall movement and separation of floor joists from sillOutward foundation wall movement and separation of floor joists from sill
Structure InspectionStructure Inspection
Separation of brick veneer from adjacent siding indicative of structural movementSeparation of brick veneer from adjacent siding indicative of structural movement
Structure InspectionStructure Inspection
Leaning/non professional pier at the crawlspace structural supportLeaning/non professional pier at the crawlspace structural support
Structure InspectionStructure Inspection
Lateral rotation of brick veneer from root intrusion to structure foundationLateral rotation of brick veneer from root intrusion to structure foundation
Structure InspectionStructure Inspection
Deterioration of Cinder Block piers from moisture at the crawlspace resulting in settlement of the structureDeterioration of Cinder Block piers from moisture at the crawlspace resulting in settlement of the structure
Structure InspectionStructure Inspection
Non professional piering/supportsNon professional piering/supports
Structure InspectionStructure Inspection
Rusted out adjustable column being used for permanent piering support of the structureRusted out adjustable column being used for permanent piering support of the structure
Structure InspectionStructure Inspection
Roll out of the outside floating slab foundation wall structureRoll out of the outside floating slab foundation wall structure
HVAC InspectionHVAC Inspection
Duct coating of sub slab ducts visible at the register boot indicative previous corrosion of ductingDuct coating of sub slab ducts visible at the register boot indicative previous corrosion of ducting
HVAC InspectionHVAC Inspection
Duct coating of sub slab ducts visible at the duct interior indicative previous corrosion of ductingDuct coating of sub slab ducts visible at the duct interior indicative previous corrosion of ducting